PM Emission Inventory CBE SD
2014-09-09
####PMEmissionInventoryCoimbatoreStudy design####
Particulate pollution level and vehicular count sample
1. A sample consists of 3 minutes of PM pollution monitoring(1-minute particle count mode, 2-minute mass mode) and 2-minute video recording.
1. Sampling carried on a CNG auto rickshaw, equipped with handheld PM monitor and a web camera based video recorder attached to right side at 0.75 meters from ground of Autorickshaw.
1. Sixty random points in Coimbatore urban limits, sampling every 4th day for 20 sampling days. Out of sixty random points, thirty random points covered in every alternative day
1. Video records reviewed for the number of the vehicle passing at the sampling point and counting vehicle types as of large, light utility, cars, and two-wheelers.
###D & D of mobile monitor### 1. corruption f SD card RPi 1. physical computing, switch press to sample and record video based on this, this, [this]( 1. suitability of pi face for that 1. open cv based python script to record the video 1. need for iron box and design of it 1. Current supply to the mobile monitor by 12V battery, 3A current supplier, 1. collocated calibration of Dylos using Aeroset, placing along with Aeroset
###Specification for mobile monitor design### 1. Need of height to get distance from two-wheeler engine heat for temp and humidity sampling. The monitor 531s placed in the top of the iron box. 1. full ventilation for Dylos is required, 1. required to check weather Dylos would work with 3 A input current from
###Past studies### 1. Studies carried with Aerocet monitor http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3068847/ http://www.mdpi.com/2305-6304/1/1/60/htm http://www.ccs.miami.edu/~nkumar/AirPollutinHelth_Del.pdf http://www.ccs.miami.edu/~nkumar/Manuscripts/NK_Andy_DAQ.pdf